Nothing in Varaverk fires when a job ends, so this picks up run records that completed
since the last pass rather than adding a hook to forty scripts. Ahead of stability in the
cycle on purpose: a wrong port is not fixed by rebooting the machine.
The reply to "shall I fix it" ends in a conf write, so the three actions are matched by
pattern with an ambiguity refusal instead of being inferred — and a phrase that supports
two readings asks again rather than picking one.
A model can be confident a port should be 8686; a probe can report that 8686 answered, and
only the second is a fact. Detecting and repairing are also separate things to trust, so
the feature runs read-only until the write switch is turned on under it.
A bug stays open until the code changes and nothing here can close it; a finding closes
itself when the probe that proved the fault starts passing, so the two cannot share a
store. Acknowledging one is scoped to the value it was acknowledged at.